麻豆传媒资源

 

Breathing easier: Inside the months鈥憀ong project to improve campus ventilation

- September 3, 2021

Up close with a device fan. (Cody Turner photos)
Up close with a device fan. (Cody Turner photos)

In the early months of the COVID-19 pandemic, everyone was focused on cleaning: hand sanitizer supply, heightened surface cleaning and everyone washing their hands like never before.

That work never stopped 鈥 you鈥檒l see a continued emphasis on cleaning, hand washing and widely available hand sanitizer on campus this fall. But we鈥檝e also all spent the past year reading about aerosols, droplets and air particles, reflecting that COVID鈥檚 primary mode of spread is airborne, typically through close person-to-person transmission.

That makes ventilation a key part of 麻豆传媒资源鈥檚 multi-layer safety plan. Efforts to improve air flow within classrooms, research labs and other spaces on campus 鈥 when combined with masks, vaccination protocols and all the other layers in Dal鈥檚 plan 鈥 is part of the complete picture to keep the Dal community healthy and safe this fall.

鈥淲e鈥檝e had a team working tirelessly on this project for months and months now,鈥 says Darrell Boutilier, director of operations with 麻豆传媒资源 Facilities Management. 鈥淚t鈥檚 a small team, but it鈥檚 a very skilled and experienced team, who has managed to do a lot of work in a relatively short period of time.鈥

Terrence Conrad, Instrument Shop working foreperson.

That team has been led by Kyle MacKenzie, who joined 麻豆传媒资源 as a utilities manager in 2019 but was embedded on campus for four years prior as a contractor with Johnson Controls, working on ventilation and control systems. In his work with Johnson, he serviced about 60 clients across the Maritimes, and prior to that he was an operator at the Queen Elizabeth Hospital in Charlottetown, running 30+ ventilation units with different requirements.

鈥淐ompared to other facilities I鈥檝e been at, I鈥檇 say it鈥檚 very good,鈥 says MacKenzie, when asked to rate the condition of Dal鈥檚 ventilation prior to all this work. 鈥淚 think we expected a lot more failures and issues, to be honest. But this was a great opportunity to give attention to the [air exchange] units and make sure everything was up to snuff.鈥

Setting the standard


麻豆传媒资源鈥檚 ventilation strategy was guided by current engineering best practice, as well as COVID-specific guidance from ventilation and facilities groups including ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) and APPA (Association of Physical Plant Administrators) in accordance with provincial and national Public Health guidelines. 听

The core of the strategy: to reduce the risk of infection from inhalation of COVID-19 by utilizing campus HVAC systems to improve air exchange rates, minimize recirculation of air and improve air filtration.

This work began in research labs, during the 鈥淩eturn to Research鈥 process last summer as the university worked to safely bring as many of Dal鈥檚 researchers as possible back to their necessary lab spaces. In total, over 165 research spaces were assessed.

鈥淢ost are already well ventilated, as they have air supply systems and fume hoods required for the research itself,鈥 explains Boutilier. 鈥淲here we found deficient airflow and had to make improvements or provide guidance, it was usually not in the labs themselves but in the shared office spaces often attached to the labs. But in general, most of our labs are very well ventilated.鈥

Into the classrooms


After research spaces, the next top priority for the Facilities team were the classroom spaces that, come September 2021, would be welcoming the majority of students and instructors back to in-person learning.


Mitchell Claridge, millwright apprentice

鈥淚f you look at ASHRAE, which is really our bible for this sort of work, we had quite a high percentage of classrooms that were already near the upper threshold for high-quality ventilation,鈥 says MacKenzie. 鈥淲e ended up focusing most of our attention on the ones that were older.鈥

Indeed, Dal鈥檚 classroom spaces are in a wide range of buildings 鈥 from newly built spaces like the Emera IDEA and Richard Murray Design Buildings all the way to the Forrest Building, which back in the late-19th century constituted the entire university campus. In total, MacKenzie鈥檚 team assessed ventilation in over 600 classroom and learning spaces. Of those, 53 were identified where air flow rate criteria were not met and remedial measures had to be taken.

Improving airflow


鈥淭he approach to improve ventilation really varied by the space,鈥 MacKenzie continues. 鈥淚t could be as simple as rebalancing the airflow in the space, or it could be installing 50 feet of ductwork. And where none of that work was feasible, we used HEPA units.鈥

Those are filtration units for spaces that lack modern ventilation systems. (One is pictured below.) 鈥淭hey have a 99.97% filtration rate. They really take every ounce of particulate out of the air and are recommended by ASHRAE in situations where you can鈥檛 access outside air.鈥

As a general practice, the team鈥檚 goal was to ensure that classroom systems exceeded a minimum target of three air changes per hour 鈥 and do whatever they could to get that number even higher, closer to four-to-six air changes per hour.

Now, air changes alone don鈥檛 tell the whole story, says MacKenzie. 鈥淚鈥檓 against setting one threshold because it鈥檚 not that simple.鈥 For example, of the few classrooms remaining with slightly lower air change rates, some have high ceilings 鈥 meaning more air space in general 鈥 while a couple others are in new buildings with some of the most high-tech air systems on campus that bring in high volumes of fresh external air (which is prioritized in industry code standards for COVID).

Classroom tips for the fall

  • Natural ventilation is one of the best ways to add more airflow to even well-ventilated spaces. Faculty and instructors in classrooms with windows will see signage encouraging them to open windows where weather permits, particularly in the fall.
  • 听If your classroom has a HEPA filter unit, please don鈥檛 try and adjust the unit yourself. You鈥檒l see contact information for Facilities Management on the device if you have concerns about noise or device quality. FM reception will be happy to help.

But overall, the 麻豆传媒资源 community can take confidence in just how much air exchange will be occurring in classrooms this fall.

鈥淥ver 80 per cent of our classes now have more than six air changes per hour,鈥 says Boutilier, 鈥渁nd we expect by the time we鈥檙e done this work in the coming days that 98 or 99% will be more than four.鈥

Strategies for offices and other spaces


For obvious reasons, the team鈥檚 top ventilation priorities have been the classroom and lab spaces which bring together the most people in a shared space at one time.

To ensure that other spaces also received guidance, Boutilier and colleague Craig Arthur from the Environmental Health and Safety team have been doing building tours with administrators, providing information on building systems and guidance for how best to manage particular spaces of concern.

鈥淲e鈥檝e probably walked through every single building in the past couple of months,鈥 says Boutilier. 鈥淲ith most offices, it鈥檚 a single person occupying the primary workspace space, and there are often windows for extra natural ventilation when available. So they鈥檙e significantly lower risk than shared spaces, but we鈥檝e still made time to work with building administrators to try and educate them on strategies people can use to manage those smaller spaces.鈥

A team effort


The arrival of students and instructors back to classrooms this September represents a big milestone for the ventilation team.


Jamie Sparrow, instrumentation mechanic, examines the computer control that supports many campus ventilation systems.

鈥淚t鈥檚 been a staggering amount of work,鈥 says MacKenzie. 鈥淭he core of our team was about three people, with other people cycled in as needed. It feels like we covered all five-and-a-half million square feet of space on campus, given how deep we were into every building.鈥

In addition to MacKenzie鈥檚 team, Boutilier credits the external partners involved in the work as well, including Matheson Air Balancing and sheet metal contractor Frank Cowie.

But for all the effort, it鈥檚 been a rewarding experience working to improving the safety of spaces across campus.

鈥淲e鈥檝e had a chance to bring some team members into this work and really develop their skills,鈥 says MacKenzie. 鈥淥ne guy wants to go back to school and do instrumentation now that he鈥檚 doing all this. So there鈥檚 some really good moments from all this.鈥